Electron and optical microscope

Task number: 4378

Reachable resolution power of the microscope is given by the wavelength of the used particles. This means that the smallest detail that we can observe has approximately the size of the wavelength. Let’s assume we want to see inside the atom which has a diameter of approximately 100 pm, this means we want to see details of approximately 10 pm.

a) What energy must the electrons have in the case we want to use electron microscope?

b) What energy must the photons have in the case we want to use optical microscope?

c) Which microscope is more practical and why?

  • Hint

    We have the de Broglie formula Broglieho vztahu  connecting the wavelength and momentum of the particle given by

    \[\lambda=\frac{h}{p} ,\]

    where h = 6.63·10−34 Js is Planck’s constant.

    Energy of the photon  is proportional to its frequency; therefore, not proportionate to its wavelength.

  • Notation

    λ = 10 pm = 10−11 m wavelength
    Ee = ? (eV) energy of the electron
    Ef = ? (eV) energy of the photon

    From tables:

    h = 6.63·10−34 Js Planck’s constant
    me = 9.11·10−31 kg electron mass
    c = 3.00·108 m s−1 speed of light in vacuum
  • Solution

    a) Momentum pe and the wavelength λe of the electron are related by de Broglie formula:

    \[\lambda=\frac{h}{p_{\mathrm{e}}} ,\]

    where h = 6.63·10−34 Js is Planck’s constant.

    We can determine the kinetic energy of the electron Ee from its momentum pe

    \[E_{\mathrm{e}}=\frac{p_{\mathrm{e}}^2}{2m_{\mathrm{e}}}=\frac{\left(\frac{h}{\lambda_{\mathrm{e}}}\right)^2}{2m_{\mathrm{e}}}=\frac{h^2}{2m_{\mathrm{e}}\lambda_{\mathrm{e}}^2}=\frac{\left(6.63{\cdot}10^{-34}\right)^2}{2{\cdot}9.11{\cdot}10^{-31}\cdot\left(10^{-11}\right)^2}\,\mathrm{J}=2.4{\cdot}10^{-15}\,\mathrm{J}=15\,\mathrm{keV}.\]

     

    b) Energy of the photon Ef is equal to

    \[E_f=hf=h\frac{c}{\lambda}=\frac{6.63{\cdot}10^{-34}\cdot3.00{\cdot}10^8}{10^{-11}}\,\mathrm{J}=1.99{\cdot}10^{-14}\,\mathrm{J}=124\,\mathrm{keV} .\]

     

    c) In terms of more resolution, the electron microscope is more practical – it is sufficient to accelerate the electrons by voltage of 1.5 kV which is not so big. In optical microscope we would need to use gamma radiation (see electromagnetical spectra ) which is hard to obtain and dangerous.

  • Answer

    To reach the desired resolution power we would need to use electrons with energy of 15 keV or photons with energy of 124 keV.

Difficulty level: Level 2 – Upper secondary level
Tasks requiring routine calculations
Tasks requiring interpretation,explanation or justification
Cs translation
Pl translation
Send comment on task by email